5.2
Downloading All Reports
After the file type and the welding process were selected, the next
screen offers a "Print All Reports" option. Selecting it will download
all welding reports, or all of the previously selected welding process,
currently in system memory in the previously selected file format.
5.3
Downloading by Commission Number, Date or Report
Range
After the file type and the welding process were selected, the next
screen offers a "By Commission Number," a "By Date Range," and a
"By Report Range" options. Depending on the selection, the ñ and
ò arrow keys can be used to select from the commissions currently
in system memory the desired one, of which the reports should be
downloaded, or the alphanumeric keypad can be used (see first info
in Sect. 4.1) to enter a start date and an end date, or the first and
the last report, that define a range of dates or a range of reports of
which the reports should be downloaded. When you press the START/
SET key, you cause the selected reports to be transferred to the stor-
age media.
5.4
Understanding the Report Download Process
The download starts automatically after a selection was made among
the options. Wait for all the selected reports to transfer and the
"Download completed" message to appear on the screen.
If a problem occurs while the download is in progress, a "Not ready"
message shows. After the problem condition is cleared, the download
resumes automatically.
If the welding unit recognizes a problem that cannot be
cleared while the data transfer is in progress, it does not
resume the process and displays a "Download cancelled"
error message. To acknowledge this error, press the START/
Info
SET key.
5.5
Deleting Data from Memory
The report data in memory can be deleted only after all welding reports
were transferred, which is indicated by the "Download completed"
message. When the storage media is unplugged, a "Delete Memory"
message appears. If the START/SET key is pressed at this point, a fur-
ther confirmation message "Delete Memory, sure?" is shown, which
has to be confirmed by pressing the START/SET key once again. Then,
the report data in memory are deleted.
5.6
Keeping Data in Memory
When the cable or storage media is unplugged, a "Delete Memory"
message is displayed. Press the STOP/RESET key to keep the current
report data in memory. They can then be printed off once again.
Make a habit of handling the internal storage as described
at the beginning of Sect. 5, to maintain data integrity and
avoid any inadvertent deletion of the reports in memory.
Important
6
Service and Repair
As the product is used in applications sensitive to safety considerations,
it may be serviced and repaired only on our premises or by partners
Version January 2018