H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
can access a sub-menu for selecting millimeters or inches as the
unit for the length.
"Inventory Number – M – " means that by pressing the MENU key,
the user can access a sub-menu for entering the number under
which the unit is inventorized with the operating company.
"Number of Tags – M – " means that by pressing the MENU key, the
user can access a sub-menu for entering the number of tags that
are printed automatically after welding with the optional label
tag printer if such a printer is connected.
"Standard – M – " means that by pressing the MENU key, the user can
access a sub-menu for selecting the standard (guideline, norma-
tive scheme) applicable to the welding operation.
4.1.3 Selecting the Display Language
When the "Select Language" sub-menu was selected, the screen
changes and the display reproduced in Display 7 appears.
Use the cursor keys ñ and ò to select one of the options, "Deutsch,"
"English," and "Français" and confirm by pressing the START/SET
key.
4.1.4 Setting the Clock
When the "Set Clock" sub-menu was selected, the screen changes and
the display reproduced in Display 8 appears.
The time of day and the date can be set using the keypad. The portions
"Hour," "Minute," "Day," "Month," and "Year" are set separately.
Press the START/SET key to confirm your settings.
4.1.5 Setting the Buzzer Volume
When the "Set Volume" sub-menu was selected, the screen changes
and the display reproduced in Display 9 appears. The buzzer can also
be heard. Turn the buzzer volume up or down to the desired value
using the ï, ð arrow keys (from 0 to 100) and confirm your setting
by pressing the START/SET key.
4.1.6 Understanding the "Recording" Sub-menu
"Welder Code on" means that the welder identification code has to
be entered as set with "Welder Code Options," "off," that this
is impossible.
"Commission Number on" means that the commission number (job
number) will have to be entered or confirmed before every new
welding, "off" that the user is not prompted to enter it.
"Joint Number on" means that the unit assigns an automatically in-
cremented joint number to every welding operation belonging
to a commission already known, and displays this number on the
screen next to the report number, "off" that no joint numbers
will be assigned at all.
"Additional Data on" means that the additional data will have to be
entered or confirmed before every new welding, "off" that the
user is not prompted to enter them.
"Fitting Code on" means that the second, so-called traceability code
of the electrofusion fitting has to be entered before every weld-
ing, "off," that this is not possible.
"Pipe Codes on" means that the codes of both pipes/components (ISO-
compliant welding and treaceability codes) have to be entered
before every welding, "off," that this is not possible.
"Pipe Length on" means that the length of both pipes/components
has to be entered before every welding, "off," that this is not
possible.
Version January 2018
HÜRNER WeldControl EF 250 User's Manual
***** LANGUAGE *****
>Deutsch
English
Francais
Display 7
Date/Time
21.06.13
14:28
Display 8
Buzzer Volume
< ------20-------- >
Display 9
CONFIGURATION **
**
>Welder Code
On
Commission No.
On
Joint No.
Off
Display 10
EN
15