Télécharger Imprimer la page

V2 ZORUS Mode D'emploi page 63

Publicité

Les langues disponibles

Les langues disponibles

PARAMETER
VALUE
Ch.AU
no
0.5"-20.0'
Ch.tr
no
0.5"-20.0'
PA.tr
no - Si
LUCi
CiCL
no
t.LUC
AUS
Mon
tiM
biSt
SPiA
FLSh
W.L
no
LP.PA
no
Si
DESCRIPTION
Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu
Function deactivated
The gate recloses after the set period time
(adjustable time from 0.5" to 20.0')
Closing after transit
During the automatic operation, the pause count down starts from the set
up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than
Ch.AU
will be used when no is set up.
Function deactivated
The gate recloses after the set period time
(adjustable time from 0.5" to 20.0')
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is
Courtesy lights
This menu allows setting the automatic operating of the courtesy lights
during the opening cycle of the gate.
NOTE: If the output is used to drive a flashing light (with internal flasher)
CiCL
select
Light on for the entire duration of the cycle
Function deactivated
Timed function (from 0 to 20')
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver
Monostable operation
Timed function (from 0 to 20')
Bistable operation
Setting low voltage exit lights
This menu makes to possible to set the flashing exit function.
Flasher operation (fixed frequency)
Indicator light operation: Indicates the status of the gate in real-time. The
type of blinking indicates the four possible conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
Function deactivated
Blinker during pause time
Function deactivated
The blinker will be on during the pause time too (gate open with
automatic closure active).
Ch.AU
is generally used.
- 61 -
DEFAULT
no
no
no
Ch.tr
CiCL
Mon
FLSh
no
MEMO

Publicité

loading