12 - PROGRAMMING THE CONTROL UNIT
-PrG
The configuration menu
items; the display shows the selected item.
i
By pressing
, you will pass to the next item; by pressing
will return to the previous item.
By pressing OK, you can view the current value of selected item
and possibly change it.
End
The last menu item (
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
i
h
By holding down the
or
keys, configuration menu items will
End
scroll fast, until item
is viewed.
In this way, you can quickly reach either the top or bottom of the
list.
PARAMETER
VALUE
EnSA
no
Si
t.APP
0.0" - 1'00
t .ChP
0.0" - 1'00
r.AP
0.0" - 1'00
r.Ch
0.0" - 1'00
t.SEr
0.5" - 1'00
no
SEr.S
Si
no
consists in a list of configurable
h
, you
DESCRIPTION
Enabling Energy Saving
Function not enabled
Function enabled
Partial opening time (pedestrian access)
If a Pedestrian Start command is received, the control unit opens the
SUPERIOR gate leaf only, for as reduced time (adjustable time from 0.0" to
1'00)
Partial closing time (pedestrian access)
In the case of partial opening, the control unit uses this time for closing.
The maximum time that can be set is equal to the closing time for the
SUPERIOR gate leaf (adjustable time from 0.0" to 1'00).
NOTE: The avoid the gate leaf not closing completely, it is recommended a
longer time be set than that used for opening
Gate leaf delay during opening
During opening, the INFERIOR gate leaf starts to move after the SUPERIOR
gate leaf, with a delay equal to the length of time set by this menu
(adjustable time from 0.0" to 1'00).
r.AP
NOTE: If
is set to
closing order of the gate leaves
Gate leaf delay during closing
During closing, the SUPERIOR gate leaf starts to move after the INFERIOR
gate leaf, with a delay equal to the length of time set by this menu
(adjustable time from 0.0" to 1'00)
Lock time
Before the opening phase begins, the control unit will energize the electric
lock in order to release it and enable the gate motion (adjustable time
from 0.0" to 1'00)
Function deactivated
Silent Locking Mode
Silent Mode (100 Hz)
WARNING: In some cases, there may be problems when unlocking.
If problems should occur, select the Standard mode
Standard Mode (50 Hz)
-PrG
t.APP
0
, the control unit does not check the correct
- 58 -
FinE
EnSA
t.APP
DEFAULT
MEMO
no
8.0"
9.0"
1.0"
5.0"
2.0"
Si