PARAMETER
VALUE
t.ASE
0.5" - 1'00
t.inv
no
0.5" - 1'00
t.PrE
0.5" - 1'00
no
Pot1
30 - 100
Pot2
30 - 100
Po.r1
0 - 60
Po.r2
0 - 60
P.bAt
Auto
Eco
no
DESCRIPTION
Lock advance time
While the electric lock is energized, the gate will stay standstill for
time (adjustable time from 0.5" to 1'00), to make its release easier.
WARNING: in case the gate has no electric lock, set the value 0
Backlash time
It could be useful to give a closing command to motors, to help the
electric lock release
Function deactivated
The control unit controls the motors in reduced power in closing
direction for the setup time (adjustable time from 0.5" to 1'00).
NOTE: the backlash precedes the electric lock release. It is possible to
reverse the order by setting a lock advance time higher then the backlash
one.
WARNING: in case the gate has no electric lock, set the value 0.
Pre-blinking time
Before any gate movement, blinker will be activated for
warn about the incoming motion (adjustable time from 0.5" to 1'00)
Function deactivated
Motor 1 power
The displayed value is the percentage of max. motor power
Motor 2 power
The displayed value is the percentage of max. motor power
Power Motor 1 during slow-down phase
The displayed value is the percentage of max. motor power
Power Motor 2 during slow-down phase
The displayed value is the percentage of max. motor power
Maximum motor power during battery operation
During battery operation, the system is powered with a lower voltage
than with mains voltage, as a result the power of the motors is reduced
compared to normal operation and may not be enough to move the doors
effectively.
This menu allows you to increase the power supplied to the motors in
order to compensate for the loss due to battery operation.
Recommended setting for 230V power supply systems and with B-PACK
buffer battery (code 161212).
When the system recognises a lack of mains power supply, it automatically
provides the increase in power.
Setting recommended for solar panel powered systems and ECO-LOGIC
kits. The system always provides an increase in power to compensate for
the reduction in voltage compared to the mains value.
Function deactivated
t.PrE
- 59 -
DEFAULT
MEMO
0.0
t.ASE
no
no
time, to
100
100
30
30
Auto