17
Electrical Connections
Connect black fan wires to black outlet wire. Connect white fan wire to
white
outlet wire and green grounding lead
wire from the grounding conductor to the supply circuit (see figure A). Use
wire connectors provided with your fan. No loose strands or loose connections
should be present. Turn splices upward and carefully push all wiring into
outlet box. When wall switches are employed, switches should be UL listed
for use with ceiling fan.
CAUTION: Always turn off power at breaker before attempting any wire
connections.
Black
Fan and lights
controlled by
remote control
unit
Ground
White
Black
Black
Light Switch
Blue
Figure B
All manuals and user guides at all-guides.com
Ground
White
Blue
Black
Green
White
Figure A
Green
White
White
Black
Fan
Switch
Light
Switch
Blue
Figure C
Setting Frequency Switches
The wall control unit is operated by a set of frequency switches and are preset
at the factory. There are two sets of frequency switches. The switches on the
wall control are located on the front panel under the insert plate. The switches
on the fan unit are located in the receiving module on top of the fan unit
(see diagram). The switches can be set in any position as long as both the
wall unit and receiving module switches are set the same. All (RF) modules
& Transmitters come from the factory with the dip switches set in the (ON)
position.
Ground
Black
Black
Green
White
1 2 3 4
HIGH
L-1
ON
MED.
L-2
LOW
REVERSE
FAN OFF
1 2 3 4
ON
12V BAT.
OFF
ON