Operation Instructions
ON/OFF
For emergency shut off.
HIGH
Controls fan motor speed. To select desired speed,
MEDIUM
press button once and release
LOW
REVERSE
Controls direction of fan blades. To reverse fan blades, press
once and release.
FAN OFF
Turns fan motor speed off. Press once to turn off. To start
motor speed again, hit one of the motor speed buttons.
L-1
Controls no function on this fan.
L-2
Controls the on/off and intensity for integrated light kit.
Push and release for on/off function. Hold down for full
range light dimming.
NOTE:
The "High", "Medium" or "Low" buttons may be used to
start the fan motor. The speed of the fan may be changed
at any time.
Common Problems
Problem A: Fan Will not Start
Remedies:
1. Check fuse or circuit breaker and replace if necessary
2. Turn off electrical power and check all wire connectors.
3. Check on/off TCS and wall control selector switch. See operation
instructions.
Problem B: Fan is Excessively Noisy
Remedies:
1. Check that all screws in fan assembly are tight and properly seated.
2. Check to make sure mounting bracket is installed properly.
3. Check to make sure light kit and glass reinstalled properly and tight.
4. If wall control is used, insure the wall control is not a transformer or a
variable speed type.
Problem C: Fan Wobbles
Remedies:
1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are screwed firmly into motor.
3. Check the weight of blades. All our blades are weighed on electronic scales.
The weight is marked on the reverse side of the fan blade near the motor
end. All of the blades should be the same weight to prevent fan from
wobbling.
4. A balancing kit is enclosed if needed.
Weight:
The weight of the complete fan, including assembly hardware is 36 lbs.