Télécharger Imprimer la page

Haier 6 Serie Instructions D'installation page 16

Masquer les pouces Voir aussi pour 6 Serie:

Publicité

Les langues disponibles

Les langues disponibles

Some models - for the gas category check the data label attached on the appliance
Cat: II 2H 3+
(Countries IT-ES-PT-IE-GB-GR-CH)
Cat: II 2E+3+
(Countries FR-BE)
Cat: II 2H3B/P
(Countries DK-FI-SE-RO)
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Double-ring (DR)
Dual (DB) - inner crown
Dual (DB) - outer crown
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Double-ring (DR)
Dual (DB) - inner crown only
Dual (DB) - outer crown only
Dual (DB) - inner & outer crown
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation, maintenance and conversion of the appliance
must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
16
16
TABLE FOR THE CHOICE OF THE INJECTORS
Nominal
Power
[kW]
1,00
1,75
3,00
3,80
0,80
3,40
G30/G31
28-30/37 mbar
G30/G31
28-30/37 mbar
G30/G31
30/30 mbar
Reduced
Ø injector
Power
[1/100 mm]
[kW]
0,40
0,45
0,75
1,50
0,40
1,50
65 (x2)
Air necessary for combustion [m
20 mbar
G20/G25
20/25 mbar
20 mbar
Ø injector
[1/100 mm]
50
66
87
98
46
95 (x2)
/h x kW)
3
2,00
3,50
6,00
7,60
1,60
6,80
8,40
G20
G20
77
101
129
141
70
/h]