- move the gate into the fully closed position (closing limit switch engaged, FCCH LED off)
- press the OK button to enter programming mode, the display will read APCH
- press and release the AP/CH button, the gate will open and the display will show OPEN
- press and release the AP/CH button to determine the starting point of deceleration on opening and the display will show the message SLO
- the gate continues slowing down until the opening limit switch trips (the FCAP LED goes out) and then automatically starts closing again, the
display shows the message CLOS
- press and release the AP/CH button to determine the starting point of deceleration on closing and the display will show the message SLO
- the gate continues slowing down until the closing limit switch trips (the FCCH LED goes out)
- the gate opens and the display shows OPEN
- press and release the AP/CH button to determine the pedestrian opening distance
- the gate continues until the closing limit switch trips (the FCCH LED goes out) the display reads END, the travel has been saved correctly.
7 . 4 P A R:
Used to modify all the parameters of the control unit, press the OK button to display the list of parameters, the display will show P01 (para-
meter number 1), the UP or DOWN button lets you scroll through the list of parameters (see parameter table).
x4
All manuals and user guides at all-guides.com
Press the pushbutton
until the parameter to
change
EN