3 . 6 C onnecting ph otocells:
Normally closed contact (when the photocells are not engaged the PHOTO LED must be on), when this input trips during closing it reverses the move-
ment, if not used then jumper between COM. and PHOTO, you must observe the polarity of the power supply for the photocells:
Fig. 9
CN1
3 . 7 Sensitiv e edge connection
Programmable input (with edge or photocell not engaged the STPA LED must be ON). if this input trips during opening it immediately reverses the move-
ment for 1.5 seconds and then stops the gate, while during closure it reverses the movement until fully open, see the parameter P06 to select the type
of edge. If not used, jumper between COM. and STPA and set the parameter P06 OFF.
Fig. 10
3 . 8 E lectrical connection w ith ph oto-test f unction activ e:
connected on the PHOTO input, with parameter P08 on 2 the control unit governs the operation of the photocells connected on the STPA input, with
parameter P08 on 3 the control unit governs the operation of the photocells connected on the PHOTO and STPA inputs. Figure 10 shows an example
of a connection with photo-test on only for the PHOTO input.
Fig. 11
CN1
All manuals and user guides at all-guides.com
CN2
17 18 19 20 21 22 23
Sw itch edge connection
17 18 19 20 21 22 23
STPA input as edge with electromechanical
switch, set parameter P06 OFF.
CN2
17 18 19 20 21 22 23
RX1
+
-
C NC NA
+
- -
COM
FOT
Relativ e sensitiv e edge connection
STPA input as resistive edge at 8.2Kohm,
set parameter P06 ON
with parameter P08 on 1, the control unit governs the operation of the photocells
RX1
+
-
C NC NA
+
-
COM
FOT
STPA
EN
RX2
TX1
+
-
C NC NA
+
17 18 19 20 21 22 23
8,2 KΩ
RX2
+
-
C NC NA
TX2
-
+
-
TX1
TX2
+
-
+
-