− Allow the filter element to dry.
− Wet the filter element with acidic
engine oil.
− Squeeze excess engine oil out of
the filter insert.
◼ Replace the filter insert in the filter
housing and secure the filter insert by
fastening the filter cover with the
clamping straps.
Battery (optional) - FX-
SG7500B only
Mounting the battery
◼ Mount the battery (B) at the
designated location.
◼ Attach the battery to the support (D)
using
the
clamping
mounting bolts (E), and nuts (A).
Connecting the battery
◼ Connect the positive wire (red) of the
generator with the electric starter to the
starter motor.
◼ Connect the ground connection
(black) to the back of the generator.
All manuals and user guides at all-guides.com
plate
(C),
◼ Connect the generator's terminal with
the electric starter first to the battery's
positive terminal and then to the
negative terminal.
When disconnecting, remove the
connection
from
terminal first and only then from the
positive terminal.
Check electrolyte level
NOTE
Check that there is sufficient electrolyte in
the battery cells.
The electrolyte level must be between
the UPPER and LOWER markings.
◼ Top up electrolyte when the electrolyte
level is below the LOWER mark.
◼ After you have topped up the
electrolyte, wait 20-30 minutes.
NOTE
The generator cannot be started until this
time has elapsed.
Operation
WARNING!
Switch off the generator under the
following conditions:
− if the power generator is left
unattended for an extended period,
− before checking, cleaning, or other work
on the power generator,
− if the generator begins to vibrate
excessively.
Preparing for operation
CAUTION!
Ensure that no loads are connected to the
are connected to the 230 V and 400 v
sockets!
the
negative
33