General safety instructions
WARNING!
Read all safety notes and instructions.
Failure to comply with the safety
instructions may result in fire and serious
injury.
Keep all safety notes and instructions
for future reference.
◼ Never run the engine of the power
generator in closed rooms or
buildings. The exhaust gases contain
dangerous carbon monoxide.
For operation in well-ventilated
rooms, additional measures must be
taken to protect against fire and
explosions - e.g., provide suitable fire
extinguishers.
◼ Only operate the generator within the
temperature range specified in this user
manual.
◼ Have all maintenance work on the
generator, except for the work listed in
this operating manual, performed by
authorized and qualified maintenance
personnel.
◼ Always switch off the generator before
carrying out any assembly, adjustment,
or maintenance work.
◼ Note that improper maintenance, non-
conforming spare parts, or the removal
or modification of safety devices can
cause damage to the device and
severe injury.
◼ Make sure that the power supply does
not get into the hands of unauthorized
persons or children!
◼ Be aware that national regulations may
restrict the use of the generator.
◼ Check the generator for significant
damage and defects before each use.
24
All manuals and user guides at all-guides.com
Original User Manual Generator FX-SG Series
◼ If necessary, have your specialist dealer
instruct you before using the generator.
◼ Only use the spare parts and protective
devices specified by the manufacturer.
Other spare parts and accessories will
invalidate the warranty and permanently
increase the user's risk of injury.
◼ Always keep the generator in good
technical operating condition.
◼ Do not operate the generator in a
humid environment. Protect the
electrical and electronic components
from the effects of moisture.
Electrical safety
◼ Ensure that connected electrical
devices, including the power cable and
plug connections, are technically
perfect.
◼ Ensure that the following total cable
length is not exceeded when using
extension cables or mobile distribution
networks:
60 meters for a cable cross-
section of 1.5 mm²
100 meters for a cross-section
of 2.5 mm².
◼ Please note that the power
generating sets' generators can only
be loaded up to their rated capacity
under the specified operating
conditions!
◼ The generator load must be restricted if
the engine and generator cooling is
limited due to the following factors:
− Operation in confined spaces
− Exceeding/falling below the
temperature operating range
− Exceeding the max. operating height
− Exceeding the max. humidity range
◼ Never connect the generator to the
mains supply yourself.