INSTALLATION
Installation
9.3
Water connection
Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
Material losses
!
The appliance may lose its function.
f Never interchange the water connections.
f Set the flow rate (see tap instructions). Observe the
maximum permissible flow rate with a fully opened
tap (see chapter "Installation / Specification / Data
table").
f Only install pressure taps in conjunction with the
safety valve.
f Observe the maximum permissible pressure (see chapter "In-
stallation / Specification / Data table").
f If necessary, fit the reducers/locking ring fittings (part of the
standard delivery) to the appliance connectors:
SHC 10 | SHC 15 Stiebel
1 Reducers from G 1/2 to G 3/8
www.stiebel-eltron.com
1
SHC 10 GB Eltron | SHC 15 GB Eltron
2 Locking ring fittings G 1/2 x 15
f Match up the colour coding on the water connections of the
tap and the appliance:
- R.h. side blue = "Cold water inlet"
- L.h. side red = "DHW outlet"
f Secure the water connections from the tap to the appliance.
Note
Ensure that the water connections are not kinked during
installation. Prevent any tensioning during installation.
9.4
Power supply
WARNING ELECTROCUTION
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING ELECTROCUTION
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
WARNING ELECTROCUTION
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.
The following electrical connections are permissible:
SHC 10 SHC 10 GB
Connection to a freely acces-
sible standard socket with
matching plug
Permanent connection to an
appliance junction box with
earth conductor
1
SHC 15
SHC 15 GB
Eltron
Stiebel
Eltron
X
-
X
X
X
X
SHC 10 | SHC 15 |
-
X
7