Power Cord—Connect
remaining wires
i
\
LJ
NOTE: Do not pre-twist stranded wire. Twist on wire connector.
Gently tug on wires to be sure both are secured.
Connect wires black to black and white to white, using UL
Listed /CSA Approved twist-on wire connectors.
Wiring configuration
Power supply wire:
Terminal box wire:
white
<«<-—--
white
black ««——-» black
ground wire ««<——»- ground connector
Power Cord—Secure cord
on strain relief
Tighten strain relief screws to secure cord.
Power Cord—Reinstall
terminal box cover
Place wires inside terminal box. Insert tabs on left side of cover.
Make sure wires are tucked inside box. Close cover ensuring
wires are not pinched. Use 4" nut driver and previously
removed screw to secure cover.
NOTE: Do not plug into outlet until instructed to do so.
15