A S A - 0 6 3
Technische Daten
Elektrik
Empfindlichkeit (80 Hz /23±3 °C)
100 mV/g
± 5 %
2
10,2 mV/m/s
± 5 %
30
20
10
0
-10
-20
-30
1
Abb. 05: Typischer Frequenzgang
der Empfindlichkeit
Genauigkeit der Empfindlichkeit
4 Hz ... 10 kHz
:
1,5 Hz / 13 kHz :
-50°C ... +120 °C :
Richtungsfaktor (80 Hz)
≤ 8 ... 10 %
Resonanzfrequenz
35kHz ± 3 kHz
Messbereich
± 80 g (U
= +24 V...+30 V) :±7%
max
± 40 g (U
= +20 V)
max
± 20 g (U
= +18 V)
max
Seite/Page 12 von/of/de 17
All manuals and user guides at all-guides.com
Technical Data
Electrical
Sensitivity (at 80 Hz /23±3 °C)
100 mV/g
10,2 mV/m/s
ASA-063 100 mV/g S/N 00002045
10
100
Fig. 05:
Typical frequency response
of sensitivity
Accuracy of Sensitivity
± 5 %
4 Hz ... 10 kHz
±3 dB
1,5 Hz / 13 kHz :
± 5 %
-50 °C ... +120 °C
Transverse sensitivity (80 Hz)
≤ 8 ... 10 %
Resonance frequency
35kHz ± 3 kHz
Measuring range
± 80 g (U
= +24 V...+30 V) :±7%
max
: ±7%
± 40 g (U
= +20 V)
max
: ±7%
± 20 g (U
= +18 V)
max
Données Techniques
Élém. élect.
Sensibilité (á 80 Hz /23±3 °C)
± 5 %
2
± 5 %
1000
Frequenz / Hz
Fig.05:
Précision de Sensibilité
:
± 5 %
±3 dB
:
± 5 %
Facteur transverse (80 Hz)
Fréquence propre
Plage de mesure
± 80 g (U
: ±7%
± 40 g (U
: ±7%
± 20 g (U
100 mV/g
± 5 %
2
10,2 mV/m/s
± 5 %
10000
100000
Courbe en réáponse type du
facteur de transmission
4 Hz ... 10 kHz
:
± 5 %
1,5 Hz / 13k Hz :
±3 dB
-50 °C ... +120°C :
± 5 %
≤ 8 ... 10 %
35kHz ± 3 kHz
= +24 V...+30 V) :±7%
max
= +20 V)
: ±7%
max
= +18 V)
: ±7%
max
ASA063_atex_DEF.doc
18.02.2013