5 OPERATION
6. Turn on the power source and close the contactor if the power source is equipped with
an output contactor control switch. Open circuit voltage must be present to operate the
wire feeder.
7. Turn the wire feeder power switch to "ON".
8. Check all gas connections for leaks.
WARNING!
Unless starting to weld, do not allow the welding wire to touch a grounded
metal surface. The welding wire becomes electrically hot when the secondary
contactor is closed. Keep fingers clear of the drive rolls; they will start turning
when the torch trigger is pressed.
9. If gas shielded wires are used, adjust the gas flow meter to the desired flow rate by
closing the torch trigger switch or operating the gas purge switch.
10. Turn off the power source and the wire feeder when they are not in use.
5
OPERATION
5.1
Overview
General safety regulations for handling the equipment can be found in the "SAFETY"
chapter of this manual. Read it through before you start using the equipment!
WARNING!
Electric shock! Do not touch the workpiece or the welding head during operation!
NOTE!
When moving the equipment, use handle intended for transportation. Never pull
the equipment by the welding torch.
CAUTION!
Before threading the wire, make sure the chisel point and burrs have been
removed from the end of the wire to prevent the wire from jamming in the torch
liner.
0558 012 634
All manuals and user guides at all-guides.com
- 14 -
© ESAB AB 2015