2.1.5. Fitting the tube-motor assembly
Fit the tube/motor assembly to the end bracket (f).
1)
Fit the tube/motor assembly to the motor bracket (g) output
2)
cable down (h).
2.2. WIRING
Cables which pass through a metal wall must be protected and isolated using a sheath
or sleeve.
Attach cables to prevent any contact with moving parts.
The cable on the Sunea CMO RTS can be removed. If it is damaged, replace it with an identical
cable.
If the drive is used outdoors and if the power supply cable is of the H05VVF type, then run the
cable in a UV-resistant conduit, e.g. trunking.
The power supply must be switched OFF when installing the product.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
Always make a loop in the power supply cable to prevent water entering the drive.
The power must be switched OFF when unmating the 2 connectors
Switch off the power supply.
-
Connect the drive according to the information in the tables below:
-
Neutral (N)
White
120V
60 Hz
h
Neutral (N)
White
120V
60 Hz
h
Do not use as a switch.
In the case of using an extension cable with fast connector:
Plug the extension cable with female i fast connector to
-
the motor extension cable with male j fast connector,
Connect the plug k of the extension cable to the wall
-
socket power supply.
Copyright
2009 - 2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
Live (L)
Black
US FAST CONNECTOR CABLE
Live (L)
Black
1
2
g
Earth (
)
Yellow/green
Earth (
)
Green
h
.
OFF
3 x 0,75 mm
2
N
L
3 x 1,5 mm
2
OFF
j
i