Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Installation Clearances
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
Cabinet opening dimensions shown are for 25" (64 cm)
and Safety, Title 24, HUD Part 280). When such standard is not
countertop depth, 24" (61 cm) base cabinet depth and
applicable, use the Standard for Manufactured Home
36" (91.4 cm) countertop height.
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
m
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
Product Dimensions
A. 18" (45.7 cm) upper cabinet to countertop
B. 22" (55.9 cm)
C. Junction box to be located in this shaded area
D. 4" (10.2 cm)
E, 20" (50.8 cm)
F. 12" (30.5 cm)
G. 5%" (14 cm)
H. Gas line opening to be located in this shaded area
1, 3%" (8.9 cm)
J. 8" (20.3 cm)
K, 30%" (76.8 cm)
A. Backguard (required for some installations)
L. 4" (10.2 cm) min. clearance from both sides of range
B. 45" (114.3 cm) overall height
to side wall or other combustible material
C. 36" (91.4 cm) cooktop height with feet
M. For minimum clearance to top of range, see NOTE".
loosened % turn
N. 30" (76.2 cm) min. upper cabinet width
D. 30" (76.2 cm) width
O. 13" (83 cm) max. upper cabinet depth
E. 26¥2" (67.3 cm) width with control panel*
F. %4" (6.4 cm) spacer
*NOTE: 36" (01.4 cm) minimum when bottom of wood or metal
G. 9%" (23.5 cm) backguard height
cabinet is protected by not less than 4" (0.64 cm) flame
retardant millboard covered with not less than No. 28 MSG
*When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
countertop; front of oven door protrudes 1%" (4.8 cm) beyond
aluminum or 0.020" (0.5 mm) copper.
24" (61 cm) base cabinet.
42" (106.7 cm) minimum clearance between the top of the
cooking platform and the bottom of an unprotected wood or
metal cabinet.
If installing a hood above the range, follow the hood instructions
for dimensional clearances above the cooktop surface.