OPERATOR FIXING
Choose measures referring to the table you can find in the
previous page, mark them on the pillars and continue as follows:
• Fix the clamps to the pillar and to the gate soldering
directly; if the material does not allow it, it is necessary to
solder the clamps to plates to be fixed to the gate and the
pillars by screws.
• Close the swing.
• Unlock the operators.
• Position CALYPSO on the brackets and fix the pins no. 1 and
no. 2 with seeger (see the picture).
• Open and close the swings repeatedly manually to verify the
absence of frictions between gate and ground.
WARNING: in order to avoid damage to the operator,
please adhere to the following conditions:
• The brackets must be installed at the same height.
• The maximum stroke of arm A should not exceed 456 mm
for CALYPSO400 (CA43, CA43M) and 556 mm for
CALYPSO500 (CA53, CA53M) (in case of gate completely
closed).
• The minimum stroke of arm B must be more than 56 mm (in
case of gate completely open).