3.0 SPECIFICATIONS
Performance Data
3.1
30
[0,49]
25
[0,40]
20
[0,32]
15
[0,24]
10
[0,16]
5
[0,08]
0
0
Note:
Pump air relief valve is factory set at 90 psi [6,2 bar] inlet air pressure, limiting the maximum hydraulic pressure to 25,000 psi [1750 bar].
Maximum hydraulic operating pressure is 21,755 psi [1500 bar].
3.2 Technical Data
Temperature
Oil Viscosity
Range
Range
-20 to +140ºF
150 -165 S.U.S.
[-29 to +50ºC]
[15 - 25 C.S.T.]
*
Actual air consumption will vary depending on application. Refer to Section 4.3 for additional information.
External Dimensions
3.3
A
ATP-1500 Air-Hydraulic Pump – Flow vs. System, Pressure
80 PSI [5,5 bar] Air Pressure
5000
[350]
Hydraulic
Oil Type
(recommended)
Enerpac HF
B
90 PSI [6,2 bar] Air Pressure
100 PSI [6,8 bar] Air Pressure
(shown for reference only – see note at bottom of graph)
10000
15000
[700]
[1050]
HYDRAULIC PRESSURE
psi [bar]
Seal
Max Hyd.
Materials
Pressure
(operating)
Buna
21,755 psi
and Viton
[1500 bar]
C
3
20000
[1400]
Sound Level
Air
Consumption*
(typical)
21 SCFM
70 dBA Max.
[113 L/Min]
Dimension
A
B
C
25000
[1750]
Weight
(including
oil)
54 lbs.
[32 Kg]
Inches (mm)
15.3 [389]
15.75 [400]
15.0 [381]