7 OVERALL DIMENSIONS AND WEIGHTS - (FIG. 3)
System
Dimensions
Flat roof 45 °
Inclined roof 0°
Weight of the empty system (*)
Full system weight (*)
Qnonsol M (**)
Qnonsol L (**)
Qnonsol XL (**)
Qnonsol XXL (**)
Storage tank
Storage tank volume
Thermal losses
Empty storage tank weight
Full storage tank weight
Length
Diameter
Electric heater
Magnesium anode
Max pressure DHW circuit
Max pressure solar circuit
Collectors
Type
Dimensions
Number of collectors
Gross area per collector
Opening area for the collector
Area of the absorber for the collector m²
Weight per empty collector
Maximum working temperature
Thermal liquid for absorber
(*) storage tank + collector/s. The brackets are not included
(**) Value calculated in terms of primary energy for electricity and/or in terms of calorifi c value for fuel, in average climatic
conditions, in load profi les M,L,XL, XXL, with permanent backup and boiler.
8 HANDLING (FIG. 4)
The tanks and the collectors come packed in expanded
polystyrene frames and stretch fi lms, where they must
remain during all transportation and storage. The col-
lectors must be transported in vertical position, in or-
der to avoid any damage. During installation keep the
collector covered until the closed circuit is fi lled with
thermal fl uid.
For the handling of the solar boiler it is always recom-
mended to use a lifting crane.
0
Do not lift the solar collector by its water fi ttings.
0
Do not lift the storage cylinder by its water fi ttings.
0
Wear suitable personal protective equipment and
use suitable safety devices.
160/2,5
L
1314
P
1903
H
2006
L
1314
P
2657
H
825
kg
93,4
kg
245,9
kWh
410
kWh
1231
kWh
2579
kWh
3716
l
151
W
68
kg
58
kg
209
mm
1230
mm
kW
1,5
Ø x mm
22 x 500
bar
10
bar
2,5
2,5
mm
1235x2020x85
1
m²
2,5
m²
2,39
2,37
kg
35,4
°C
l
1,55
9 PREPARING FOR INSTALLATION (FIG. 7)
Select the best possible orientation for the solar collec-
tors (ideally facing south). Avoid positions that are shad-
ed by plants, trees, buildings or hills, etc. during the day.
Maintain the minimum distance (A) between the system
and the edge of the roof.
Remove all gravel and detritus from the surface on which
the system is to be installed.
The mounting kit must not be used to install other su-
perstructures. It is designed only for use with our solar
water heating systems.
The installation of a solar water heating system modifi es
the existing structure of the roof. Verify the suitability of
all roof elements and if necessary adapt them to avoid
leaks or damage by wind and/or snow loads.
18
200/2,5
200/4
1526
2586
1903
1626
2006
1727
1526
2586
2657
2197
825
825
108,4
131,3
299,9
324,1
410
279
1187
863
2500
1930
3629
2937
190
190
84
73
73
263
263
1526
1526
Ø500
1,5
1,5
26 x 450
26 x 450
10
10
2,5
2,5
2,5
2
1235x2020x85
1235x1625x85
1
2
2,5
2
2,39
1,91
2,37
1,9
35,4
29,15
180
1,55
1,38
Termosyphon solar system
160/2,5 200/2,5 200/4
A
1
1
300/4
300/5
2586
2586
1626
1903
1727
2006
2586
2586
2197
2657
825
825
154,3
166,8
433,1
445,9
270
218
802
679
1790
1536
2729
2376
276
276
126
96
96
372
372
2150
2150
1,5
1,5
26 x 450
26 x 450
10
10
2,5
2,5
2
2,5
1235x1625x85
1235x2020x85
2
2
2
2,5
1,91
2,39
1,9
2,37
29,15
35,4
1,38
1,55
U.M.
300/4
300/5
1,5
1,5
1
m