All manuals and user guides at all-guides.com
?
E013
no measured value available
l
à sensor in boot phase
à Sensor does not find an echo, e.g. due to faulty installation or
wrong parameter adjustment
?
E017
Adjustment span too small
l
à Carry out a fresh adjustment and increase the distance
between min. and max. adjustment
?
E036
no operable sensor software
l
à Carry out a software update or send the instrument for repair
?
E041, E042, E043
Hardware error, electronics defective
l
à Exchange instrument or return instrument for repair
Depending on the failure reason and measures taken, the steps
described in chapter "Set up" must be carried out again, if necessary.