The following applies to all other applications (e.g. as measuring cylinder):
·
Use one−way flow control valves GRLA
to set the swivel speed.
These are screwed directly into the
compressed air ports (for this, remove the
standard connection with colour code).
·
Connect the DSMI tubing.
For eccentric masses:
·
Check whether controlled HGL non−return valves or a VZS compressed air
compensation reservoir are necessary.
In this way you can prevent the moving mass from moving down and hitting the
bottom if there is a sudden drop in pressure.

Electrical installation

Note
Leakage currents can impair the measuring system.
· Make sure that the earth connection 6 is connected with the earth potential
(earth cable optionally either with eyelet or blade connector).
The cable cross section of the earth cable must be at least 2.5 mm
cable length must not exceed 0.5 m.
Insert the supplied screw aC with cutting
·
thread into the hole for the earth
connection 6.
This will ensure the electrical contact in
spite of the anodising layer.
Festo DSMI−...−B 1003a English
Fig. 18
6
Fig. 19
2
and the
aC
33