Electrical Installation; Circuitry Installation - Festo EGSK-15 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
EGSP/EGSK

Electrical installation

To protect the end positions against uncontrolled overtravel:
Check whether additional hardware proximity switches are necessary
S
If inductive proximity sensors are used as hardware proximity switches:
Use proximity switches with normally−closed function.
S
If the proximity switch cable is ruptured, the normally−closed function prevents
the EGSP/EGSK from passing the end position.
Avoid external influence caused by strong magnetic fields or ferrite parts in the
S
vicinity of the proximity switches (at least 10 mm space).
If proximity sensors are used as reference switches:
Use the Sensor Rail" kit with switch lugs and sensor profile (è catalogue
S
specifications, www.festo.com/catalogue).
Use the inductive proximity switch of type SIES−8M, according to the input of
S
the control used.
To prevent contamination:
Use the slot covers from our catalogue.
S

Circuitry installation

Note
If used in safety−relevant applications, additional measures are necessary. In
Europe, for example, the standards in the EC machinery directive must be
observed.
Without additional measures in accordance with statutory minimum
requirements, the product is not suitable for use in safety−related sections of
control systems.
28
.
Festo EGSP/EGSK 0901NH English

Publicité

Table des Matières
loading

Table des Matières