PROGRAM TIMER operation
The timer operations of the combination of ON and OFF TIMER. Once this has been set the timer operations will be repeated at the
same time every day unless the ON/OFF button is pressed.
Comfort Start-up
In ON-TIMER operation, the unit starts the operation a little earlier, so
that the room can approach optimum temperature at ON time. This is
so called "Comfort start-up".
• Mechanism
The room temperature is
checked 60 minutes before
the ON time. Depending on
the temperature at that time,
the operation starts 5 to 60
minutes before the timer is at
Set temperature
ON.
• The function is available for
both COOL and HEAT opera-
tion mode (including AUTO).
It does not work for DRY
mode.
ALLERGEN CLEAR operation
All manuals and user guides at all-guides.com
Example: When it is prefered to stop at 22:30, and then start operation at 8:00,
OFF-TIMER operation setting
Set by the procedures on page 11.
ON-TIMER operation setting
Set by the procedures on page 12.
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control unit. The display will
change depending on the operational status.
Changing of set time
Set a new time by using the OFF-TIMER or ON-TIMER button.
How to cancel
Press the CANCEL button to turn off the timer display.
When SLEEP TIMER is selected, the set temperature is automatically
adjusted after a while, ensuring that the room is not too cold during
cooling or too warm during heating.
• During cooling : the preset temperature is lowered by 1°C at the start
In COOL operation
(Stop) Operation starts
(Operation)
• During heating: Preset temperature is lowered by 1°C at the start of
Check the room
Set time
temp. 60 mins.
before.
The power of enzymes is used to eliminate allergy-causing allergens that accu-
mulate on the allergen clear filter.
Aim the remote control at the air-conditioner.
1
Press the ALLERGEN CLEAR button.
NOTE
• Since the room temperature may change quite a bit, it is recommended
that this be used when no one is in the room. (It completes automati-
cally in approximately 90 min.)
• During ALLERGEN CLEAR operation temperature, fan speed, airflow
direction and timer operations settings cannot be made.
– 13 –
near the set temperature.
Set to
Set to
With ON-TIMER, the air conditioner starts running.
Then, with OFF-TIMER, the air conditioner stops run-
ning.
With OFF-TIMER, the air conditioner stops running.
Then, with ON-TIMER, the air conditioner starts run-
ning.
SLEEP TIMER
of SLEEP operation (when the timer is set). After that, the tempera-
ture goes up by 1°C every an hour to become 1°C higher than the
present temperature.
SLEEP operation (when the timer is set). After that the temperature
to becomes 3°C lower in an hour and 6°C lower in two hours than the
present temperature.
Press the ON/OFF or
To stop:
ALLERGEN CLEAR button.

Publicité

loading

Ce manuel est également adapté pour:

Srk71zk-sSrk80zk-s