6.
Once the reading stabilizes, read the value. If the polarity is twisted a
"Minus sign" is displayed.
Continuity test
Before making any measurements, make sure the circuit is disconnected from
any power source and all capacitors are properly discharged!
1.
Switch on the device with the rotary switch.
2.
Attach the pin-plug of the black test lead to the COM-jack and the
pin-plug of the red test lead to the VΩ-jack.
3.
Touch the measuring points with the probe tips.
4.
If the resistance is less than about 50 Ω, you hear an audible signal. If the
circuit is open, (>10 MΩ) the display shows "- - - -".
Frequency measurement
1. Switch on the device with the rotary switch.
2. Attach the pin-plug of the black test lead to the COM-jack and the pin-plug
of the red test lead to the VΩ-jack.
3. Touch the measuring points with the probe tips.
4. Once the reading stabilizes, read the value.
Non Contact Voltage tester (NCV)
To turn on the NCV function, press the NCV key (8) for two seconds. The NCV
symbol appears on the display.
Keep the tip of the measuring device to a power outlet or a cable and
press the NCV key. In the presence of dangerous voltage, (>90 V AC) a
signal tone sounds and the LED indicator lights up.
Attention!
Even without an alarm, dangerous voltage can be concerned! This depends on
various factors. Therefore, if necessary, check the zero voltage with the
voltmeter.
In the NCV-mode, voltage, current or resistance cannot be measured at the
same time.
Hz
EN 15