MAINTENANCE AND SERVICE
This Power-Vent has no user-serviceable mechanical components.
Contact your dealer or a qualified gas appliance service technician
for all service and repair.
CHECK VENT SYSTEM
The fireplace and venting system should be inspected before initial
use and at least annually by a qualified service person. Inspect the
external vent cap on a regular basis to make sure that no debris is
interfering with the air flow.
FOR HIGH WIND APPLICATIONS, A WIND SHIELD IS PROVIDED
WITH THE UNIT.
1.
Remove the front fascia by removing (6) #10-24 X 3/8 inch
screws. See Figure 53.
2.
Turn fascia over and attach wind shield with (1) #8 X 1/4 inch
screw, as shown in Figures 56 and 57.
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
Page 32
POWER VENT
HIGH WIND APPLICATIONS
Figure 56
Figure 57
PAINTING POWER-VENT
Front fascia and inlet air box can be painted if desired. All surfaces
to be painted must be thoroughly cleaned and scuffed with steel
wool. Paint must have temperature rating over 750° F.
GENERAL INFORMATION
NOTE: The Power-vent inducer fan will run for 15 seconds after
the fireplace is turned on. After this pre-purge time the ignition
sequence will be initiated.
NOTE: The Power-vent inducer fan will run for 120 seconds after
the fireplace is turned off to purge the system of exhaust gases.
3.
Make 3 hand bends on wind shield as shown below in
Figures 58, 59, and 60.
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
FASCIA SHIELD REMOVED FOR CLARITY
Figure 58
Figure 59
Figure 60
43902-0-1021