Rough Opening For Floor Level Installation
Rough Opening For Elevated Installation
Page 22
INSTALLATION
B
Figure 29
B
Figure 30
A
Rough Opening For Installing In Corner
The fireplace can be mounted on any of the following surfaces:
1.
A flat, hard combustible or non-combustible surface.
2.
A raised wooden platform.
3.
Four corner supports. (Example: Four concrete masonry
blocks.) These supports must be positioned so they contact
all four perimeter edges on the bottom of the fireplace, if
A
allowed by local codes.
NOTICE: Verify the gas supply and electrical considerations
before beginning the framing.
Framing Information
Fireplace framing can be built before or after the fireplace is set
in place. Position framing to accommodate wall covering and
fireplace facing material. Construct the fireplace framing with
2 x 4 lumber or heavier. Refer to the INSTALLATION TABLE
below for minimum framing dimensions.
Before construction begins, measure fireplace dimensions
and verify framing methods and wall covering details.
INSTALLATION TABLE - MINIMUM DIMENSIONS (In Inches)
Model
DVCTL60
59-7/8
Figure 31
CAUTION
A
B
C
D
75-1/8
23-1/2
85-5/16 115-1/2
E
F
57-3/4
43902-0-1021