Installation
All installation must be carried out by a competent person or qualifi ed electrician. Before connecting
the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
The appliance must be connected directly to the mains using an omnipolar circuit-breaker with a
minimum opening of 3 mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it complies
with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power cord for damage. If the supply cord becomes damaged, it must be
replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid
a hazard.
WARNING: This is a Class I appliance and MUST be earthed.
This appliance is supplied with a 4 core mains cable coloured as follows:
Brown = L2
Black = L1
Blue = N or Neutral
Green and Yellow = E or Earth
WARNING: Securely crimp the two Live cables together (L1 and L2) before connecting
them to the Live terminal of the mains supply.
WARNING: Before obtaining access to the terminals, all supply circuits must
be disconnected.
This appliance requires a 32 amp Miniature Circuit Breaker.
To avoid the risks that are always present when you use an electrical appliance it is important that
this appliance is installed correctly and that you read the safety instructions carefully to avoid misuse
and hazards. Please keep this instruction booklet for future reference and pass it on to any future
owners. After unpacking the appliance please check that it is not damaged. If in doubt, do not use the
appliance but contact Customer Services - see end of Care & Maintenance section for details.
Yellow / Green
4
Blue
N
3
Brown
L2
2
Black
L1
1