Vmf-E5 Panel Main Display; Vmf-E5 Panel Main Screen - AERMEC VMF-E5 Manuel D'utilisation

Masquer les pouces Voir aussi pour VMF-E5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VMF-E5 panel main display

During normal functioning of the system,
the VMF-E5 panel display shows the
standard window. This window contains
the information on the system status
and this information will allow the user
to have a clear indication regarding
functioning of the WRL unit as well as
supply any error and/or malfunctioning
messages.
Should the user enter any menu and
not press any key for a time longer than
that set in the screen saver function, the
system will automatically return to the
main screen.
38
GB
6795770_02

• VMF-E5 panel main screen:

A
L
WED
25/02/09
I
Key
Function
Indicates the status of the system:
A
- if the (
) icon is present then the VMF system is active;
- if no icon is present then the VMF system is off.
Indicates the season selected for the VMF system:
B
- the (
) icon indicates that the system is working in summer mode;
- the (
) icon indicates that the system is working in winter mode.
Indicates the functioning status of the fan coils:
C
- if the (
) icon is present then at least one fan coil of the VMF system is active;
- if no icon is present, then all the fan coils of the VMF system are inactive.
Indicates the percentage of power demanded by the fan coils of the VMF system.
Each bar displayed represents 20% of the total installed power (by total power
D
we mean the sum of the power outputs of all the fan coils making up the VMF
system). It can therefore be between 0% (no fan coil demands power) and 100%
(all the fan coils are active) with intervals of 20%.
Indicates an alarm status; the signal may represent different situations which can
be recognised by the type of icon displayed:
- No icon means that no alarms are currently active;
E
- (
) an alarm is in progress which is not yet displayed in the alarm log;
- (
) an alarm is in progress which is already displayed in the alarm log;
Should an alarm be triggered, these icons will continue to be displayed until the
cause of the alarm is resolved.
Indicates whether a time period has been set in the system (for least one fan coil
F
or for production of domestic hot water).
G
Indicates the time of the system (hours/minutes/seconds).
H
Indicates the date of the system (day/month/year).
I
Indicates the day of the week.
L
Indicates the room temperature read by the probe on the VMF-E5 panel.
B
c
20.7
11:22:37
H
G
C
D
E
ON
OFF
F

Publicité

Table des Matières
loading