Technical Data - Steinberg Systems SBS-MR-1600/6 Manuel D'utilisation

Agitateur magnétique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
The operation manual must be reviewed.
Never dispose of electrical equipment together
with household waste.
This machine conforms to CE declarations
Attention! Hot surface may cause burns.
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details it
may differ from the actual machine.
The original operation manual is in German. Other
language versions are translations from German.
USER MANUAL
SAFETY INSTRUCTIONS
General safety information for the use of electrical devices:
To avoid injury from fire or electric shock, please ensure
compliance with safety instructions when using this device.
Please read the instructions carefully and make sure that
you have understood them well. Keep the manual near the
equipment to be able to read it at any time. Always use
current sources connected to the ground and providing the
necessary voltage (indicated on the label on the device).
If you have any doubt, let an electrician check that your
outlet is properly grounded. Never use a damaged power
cable. Do not open the unit in damp or wet environment,
or if your hands or body are damp or wet. Protect the unit
from solar radiation. Use the device in a protected location
to avoid damaging the equipment or endangering others.
EN
Make sure the device is able to cool and avoid placing
it too close to other devices that produce heat. Before
cleaning, disconnect it from the power source. Use a soft
damp cloth for cleaning. Avoid using detergents and make
sure that no liquid enters the unit. No internal element of
this device needs to be maintained by the user. Opening
the device without our approval leads to a loss of warranty!
SAFETY GUIDELINES
1.
Please read and understand these instructions
carefully before operating the device! Please observe
the safety guidelines carefully in order to prevent
damages through improper use!
2.
Please keep this manual available for future
reference. If this device is passed on to third parties,
the manual must be passed on with it.
3.
Only use this device indoors and for its intended use.
4.
We do not offer any warranty for damages resulting
from improper use or incorrect operation.
5.
Before the first use, please check whether the main
voltage type and current comply with the indicated
data on the type plate.
6.
This device is not intended to be used by persons
(including children) with limited physical, sensory
or mental aptitude or lack of experience and/or
knowledge, unless they are supervised by a person
responsible for their safety or have received
instruction from this person as to how the device is
used.
7.
ELECTRIC SHOCK HAZARD! Do not attempt to repair
the unit yourself. In case of device failures, repairs
must be done by qualified experts.
8.
Please check main plug and power cable regularly.
If the power cable for this device is damaged, it has
to be replaced by the manufacturer or its customer
service or another qualified person in order to
prevent hazards.
U S E R M A N U A L
9.
Prevent damages to the power cable by avoiding
squeezing or bending it or rubbing it on sharp edges.
Also keep the power cable away from hot surfaces
and open flames.
10.
ATTENTION! DANGER TO LIFE! While cleaning, never
immerse the device in water or other liquids.
11.
Under no circumstances should the housing be
opened.
12.
The device is designed for internal use only.
13.
Do not use the device at altitudes above 2000 m.
14.
For use safety ensure the device housing is earthed.

TECHNICAL DATA

Product name
Magnetic
Magnetic
Magnetic
Stirrer
Stirrer
Stirrer Timer
Timer
Professional
Model
SBS-MR
SBS-MR
SBS-MR
-1600/6
-1600/1T
-1600/1T
PRO
Rated voltage
230/50
[V~]/Frequency
[Hz]
Power [W]
870
310
660
Protection class
IP 30
Temperature
5-99
5 – 100
0-220
range [°C]
Maximum
1600
rotational
speed [rev/min]
Volume of
100
100
5000
agitated
-1000
-5000
substance [ml]
Number of
6
1
1
workstations
Work surface
161x161
187x187
φ120
dimensions
[mm]
Dimensions
301x963
195x266
310x209
[mm]
x131
x168
x140
Maximum
301x963
195x266
310x209
dimensions
x390
x443
x525
incl. mounted
accessories
[mm]
Timer [min]
0-120
0-120
0-9999
Ambient
15-25
temperature
[°C]
Weight [kg]
10,8
4,2
5,1
SCOPE OF APPLICATION
The magnetic agitator is a device designated for general
use in laboratories, schools, universities and similar
establishments. Used for contactless liquid agitation in
glass laboratory vessels, such as flasks, beakers, etc.
The product is outside of the scope of MDD 93/42/EEC
Medical Devices regulations.
8
Rev. 06.03.2018
It is not a medical device and should not be used for
medical research and tests in hospitals and other health
facilities.
The user is liable for any damage resulting from non-
intended use of the device!
BERORE THE FIRST USE
Upon receipt of the goods, check the packaging for
integrity and open it. If the packaging is damaged, please
contact your transport company and distributor within 3
days, and document the damages as detailed as possible.
Do not turn the package upside down! When transporting
the package, please ensure that it is kept horizontal and
stable.
DISPOSING OF PACKAGING
Please keep all packaging materials (cardboard, plastic
tapes and Styrofoam), so that in case of a problem, the
device can be sent back to the service centre in accurate
condition!
INSTALLING THE APPLIANCE
APPLIANCE LOCATION
Do not use in ambient temperatures outside of the 15-
25°C range and if relative humidity exceeds 60%. Ensure
good ventilation in the room in which the device is to be
used. The distance between the back of the chain toaster
and the wall should be at least 20 cm, minimum distance
between the sides of the device and the walls should be
at least 10 cm on each side and 35 cm between the top
of the device and the ceiling. Keep the device away from
hot surfaces. Operate the device on flat, stable, clean,
refractory and dry surfaces out of the reach of children and
people with mental disabilities. Install the device making
sure that constant access to the main plug is ensured. The
power cord connected to the appliance must be properly
grounded and correspond to the technical details! Voltage
fluctuation should not exceed ±10% of the rated value.
DEVICE OPERATION – BASIC PRINCIPLES
SBS-MR-1600/6
4
3
2
1
5
6
8
7
SBS-MR-1600/1T
SBS-MR-1600/1T PRO
3 4
4
2
5
5
2
1
6
6
7
8
7
8
Rev. 06.03.2018
1.
Stand base
2.
Rod
3.
Attachment
4.
Clamp
5.
Temperature sensor
6.
Work surface
7.
Control panel (see description below)
8.
ON/OFF switch
User assembly of the temperature sensor stand is required.
To do that:
Screw the threaded end of the rod (2) to base (1).
Slide attachment (3) onto the rod (2) and tighten
screw.
Insert clamp (4) rod through the hole in the
attachment and tighten screw.
Insert temperature sensor into one of the holes in
the clamp's plastic part.
The device is ready for use.
Control panel of SBS-MR-1600/6 i SBS-MR-1600/1T
1
2
5
9
3
4
8
1.
Temperature display
2.
Increase value button
3.
Decrease value button
4.
„SET" button
5.
Rotational speed display
6.
Timer
7.
ON/OFF switch
8.
Rotational speed adjustment knob
9.
Diode
Temperature display abbreviations:
SV – Setting Value
PV – process variable / OUT – Output – process variable for
PID controller (current temperature reading)
Control panel of SBS-MR-1600/1T PRO
3
10
1
2
6
4
5
11 12
9
7
8
1.
Alarm diode
3
2.
Rotational speed display
3.
Rotational speed adjustment button
4.
„OFF" diode
5.
Time display (timer)
1
6.
Time setting adjustment button
7.
„OUT" diode
8.
Temperature display
9.
Temperature setting adjustment button
10.
Heating, agitation and timer On/Off switch
11.
Automatic adaptation function button
12.
„SET" button
9
6
7
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sbs-mr1600/1tSbs-mr1600/1t pro

Table des Matières