Assembly
Assembly and installation of the device must be carried out by a specialist familiar with the
hazards and the relevant regulations. Maintenance, operation and commissioning of this
device must only be carried out by qualified persons.
When choosing a location for your device, make sure to avoid impact, vibration, dust, hot and
cold temperatures and dampness. Furthermore, no powerful transformers or motors must be
used close to the device.
The effect light must only be operated at a maximum ambient temperature of 45°C. The
maximum casing temperature is 60°C.
The device must be mounted out of normal reach.
Illuminated objects or surfaces must be at least 0.1m away from the device's light emission
source. Easily flammable materials like decorative fabrics must have a distance of at least 0.5m
to the device. Otherwise, such objects may catch fire!
When mounting the product, make sure that the power cord is neither jammed nor damaged by
sharp edges.
During installation or service work, the area below the place of installation must be cordoned
off.
The installation surface or mounting fixture needs to be designed in a way that it can take
10 times its load capacity for at least 1 hour without permanent damaging deformation.
It is also essential that the device is secured by means of a second safety restraint that is
independent of the actual mounting supports when installing it in an elevated position. No part
of the installation must fall down if the main suspension system fails.
Observe all relevant regulations of your country when installing the device.