9. Troubleshooting
Problems
Load connected to the generating set during start-up.
Air filter (fig. A – No.14) blocked.
Fuel level too low
Engine does not
Fuel filter (fig. A – No.13) blocked.
start
Oil level too low.
Starter battery (fig. A – No.15) defective.
Fuel supply blocked or leaking.
Fuel level too low
Engine stopped
Oil level too low.
Circuit breakers (fig. A – No. 8) not activated.
Defective devices supply lead
No electric
current
Defective electrical sockets (fig. A - No 9).
Defective alternator.
Device connected or faulty lead.
Triggering the
circuit breakers
Overload (see § Capacity of the generating set).
10. Specifications
Model
Maximum output / Rated output
Acoustic pressure at 1 m
Engine type
Recommended fuel and fuel tank capacity
Recommended oil and oil sump capacity
Oil failure cut-out
Circuit breaker
Direct Current
Alternating Current
Socket types
Spark plug type
Battery
Dimensions L x l x h
Weight (without fuel)
● : Standard
Probable causes
○ : Option
Disconnect the load.
Clean the air filter (see § Cleaning the air filter).
Fill up with fuel (see § Filling up with fuel).
Replace the fuel filter (see § Replacement of the fuel
filter).
Check
(see. § Checking of oil level).
Recharge or replace the starter battery.
Have it checked, repaired or replaced.*
Fill up with fuel (see § Filling up with fuel).
Check
(see. § Checking of oil level).
Activate the circuit breakers.
Change the lead
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Disconnect the device and the lead.
Remove the overload.
* Operation(s) to be entrusted to one of our agents.
Diesel oil
SAE 5W40
230V – 10A
2P+T 230V 10/16A
X : Not applicable
Possible solutions
the
oil
level
and
fill
the
oil
level
and
fill
DIESEL 6500 TE XL C
5200 W / 4160 W
95 dB(A)
Kohler KD440
●
●
X
400V – 6A
3P+T+N 400V 16A
X
●
81 x 55.5 x 59 cm
103 kg
up
if
necessary
up
if
necessary
16 L
1.5 L