Scope of supply
3.1 Basic device
The heat pump contains the components listed below.
The refrigeration circuit is "hermetically sealed" and contains
the fluorinated refrigerant R407C included in the Kyoto proto-
col. Information on the GWP value and CO
refrigerant can be found in the chapter Device information. The
refrigerant is CFC-free, non-ozone depleting and non-combus-
tible.
1
5
8
6
1)
Evaporator
2)
Liquefier
3)
Fan
4)
Switch box
5)
Compressor 1
6)
Compressor 2
3.2 Switch box
The switch box is located in the heat pump. It can be swung out
after removing the lower front cover and loosening the fasten-
ing screw located in the upper left-hand corner.
The switch box contains the supply connection terminals as
well the power contactors and the soft starter unit.
EN-4
equivalent of the
2
11 11
10
10
7)
8)
9)
10) Collector
11) Dirt trap
3.3 Heat pump manager
Use the heat pump manager included in the scope of supply to
operate the air-to-water heat pump.
The heat pump manager is a convenient electronic regulation
and control device. It controls and monitors the entire heating
system based on the external temperature, as well as domestic
hot water preparation and safety systems.
The customer must install the external temperature sensor,
which is included in the scope of supply of the unit heat pump
and heat pump manager together with the necessary fixing ac-
cessories.
The enclosed operating instructions describe the function and
use of the heat pump manager.
452163.66.89 · FD 0006
3
4
2
Filter dryer
Expansion valve
Inner heat exchanger
LA 60S-TU
9
7
www.glendimplex.de