Télécharger Imprimer la page

Pentair HYDROMATIC HUP4 Notice D'utilisation page 2

Pompes utilité submersibles

Publicité

Les langues disponibles

Les langues disponibles

Safety . Specifications
Important Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for
one of the following signal words and be alert to the
potential for personal injury!
indicates a hazard which, if not avoided,
will result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to personal
injury.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition. Replace missing
or damaged safety labels.
California Proposition 65 Warning
This product contains chemicals known
to the State of California to cause cancer or birth
defects or other reproductive harm.
Risk of explosion. Do not ground to a gas
supply line. Pump water only with this pump. Failure to
follow this warning can result in personal injury and/or
property damage.
Risk of flooding. Can cause personal
injury and/or property damage. If a flexible discharge
hose is used, make sure pump is secured in sump to
prevent movement. Failure to secure pump may allow
pump movement, switch interference and prevent
pump from starting or stopping.
Risk of sudden starts. Can cause
electrical shock and personal injury. Pump motor is
equipped with an automatic resetting thermal protector
and may restart unexpectedly.
Risk of electric shock. Can shock, burn or
kill. This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conductor
cord and 3-prong, grounding-type plug. Be certain that it
is connected to properly grounded, grounding-type
receptacle.Where a 2-prong wall receptacle is
encountered, it must be replaced with properly grounded
3-prong receptacle installed in accordance with the
National Electrical Code and local codes and ordinances.
1. Know the pump application, limitations, and potential
hazards.
2. Make certain power source conforms to requirements
of your equipment.
3. Disconnect power before servicing.
4. Release all pressure within system before servicing
any component.
5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An
unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
7. Check hoses for weak or worn condition before each
use, making certain all connections are secure.
8. Periodically inspect pump and system components.
Keep sump, pump and system free of debris and
foreign objects. Perform routine maintenance as
required.
9. Provide means of pressure relief on pumps whose
discharge line can be shut-off or obstructed.
10. Personal Safety:
a. Wear safety glasses at all times when working
with pumps.
b. Keep work area clean, uncluttered and properly
lighted. Replace all unused tools and equipment.
c. Keep visitors at a safe distance from the work
area.
d. Make workshop child-proof – with padlocks,
master switches, and by removing starter keys.
12. When wiring an electrically driven pump, follow all
electrical and safety codes, as well as most recent
National Electrical Code (NEC) and Occupational
Safety and Health Act (OSHA).
13. All wiring should be performed by a qualified
electrician.
14. Protect electrical cord from sharp objects, hot
surfaces, oil, and chemicals. Avoid kinking
cord. Replace or repair damaged or worn cords
immediately.
15. Use wire of adequate size to minimize voltage drop at
motor. Refer to most recent National Electrical Code.
16. Do not touch an operating motor. Modern motors are
designed to operate at high temperatures.
17. Do not use in water where fish are present.
Specifications
Horse Power..............................................................1/4
Power supply required...............................115V, 60 HZ.
Liquid Temp. Range.............................Max. 77°F (25°C)
Operation Position..............................................Vertical
Individual Branch Circuit Required ....................15 Amp
Operating Depth
Beginning min..........................1/2"
(water level)
Ending max.............................3/16"
Discharge..............................................1" NPT (25 mm)
2

Publicité

loading