2.11 CHARGING THE BATTERY
Do not permit smoking, open flame, sparks or any
other source of heat around a battery. Wear protective
goggles, rubber apron and rubber gloves when
working around a battery. Battery electrolyte fluid is an
extremely corrosive sulfuric acid solution that can cause
severe burns. If spill occurs flush area with clear water
immediately.
Storage batteries give off explosive hydrogen gas while
recharging. An explosive mixture will remain around the
battery for a long time after it has been charged. The
slightest spark can ignite the hydrogen and cause an
explosion. Such an explosion can shatter the battery and
cause blindness or other serious injury.
Use battery charger plug to keep the battery charged and ready
for use. Battery charging should be done in a dry location.
1. Plug charger into "Battery Charger Input" jack, located on the
control panel. Plug wall receptacle end of the battery charger
into a 120 Volt AC wall outlet.
2. Unplug battery charger from wall outlet and control panel jack
when generator is going to be in use.
Do not use the battery charger for more than 48 hours at one
charge.
3.1 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil and Oil Filter‡
Clean Spark Arrestor Screen
Service Air Filter
Replace Spark Plug
‡
Change oil after first 30 hours of operation then every season.
*
Change oil and oil filter every month when operating under heavy load or in
high temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if very dirty.
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
Model # ....................................................................................005847
Rated Max. Power ...................................................................8.0 kW**
Surge Power ................................................................................10 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................33.3 Amps**
Current @ 120V .............................................................66.6 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
(XG7000E & XG8000E)
NOTE:
At Each Use
*Every Season/Every 100 Hours
**Every Season/Every 100 Hours
**Every Season/Every 200 Hours
Every Season
Model # ....................................................................................005845
Rated Max. Power ...................................................................7.0 kW**
Surge Power .............................................................................8.75 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .............................................................29.2 Amps**
Current @ 120V .............................................................58.3 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.
3.2.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM ....................................................14.5
Displacement ............................................................................... 410cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Gap ............................................... 0.030 inch or (0.76 mm)
Gasoline Capacity ............................................................ 9 U.S. gallons
Oil Type.................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ................................................ w/ Filter Change = 1.5 Qts.
Run Time/Fuel Consumption-1/2 Load .. 10 Hours / .73 gallons per hour
Class II Emission Certified
3.2.3 EMISSIONS INFORMATION
The Environmental Protection Agency (EPA) requires that
this generator comply with exhaust and evaporative emission
standards. This generator is certified to meet the applicable EPA
emission levels on gasoline. The emission control system on this
generator consists of the following:
• Fuel System
~ Carburetor
~ Fuel Tank/cap
~ Fuel Lines
~ Evaporative Vent Lines
• Exhaust System
~ Exhaust Manifold
~ Muffler
It is important to perform the service specified in the Maintenance
Schedule to ensure that the generator complies with the applicable
emission standards for the duration of its useful life. Additionally,
emissions critical maintenance must be performed as scheduled
in order for the Emissions Warranty to be valid. Emissions critical
maintenance consists of servicing the air filter and spark plugs in
accordance with the Maintenance Schedule. Service and repairs
may be performed by any capable person or repair shop.
Maintenance
w/o Filter Change = 1.2 Qts.
• Air Induction System
~ Intake Pipe/manifold
~ Air Filter
• Ignition System
~ Spark plug
~ Ignition module
• Exhaust System
~ Exhaust Manifold
11