Télécharger Imprimer la page

Abus eyseo TV7220 Instructions D'installation page 281

Masquer les pouces Voir aussi pour eyseo TV7220:

Publicité

PARAMETER
VALUE
do<num>
0, 1
return
<return page>
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=1
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
[di1=<state>]\r\n
[di2=<state>]\r\n
[di3=<state>]\r\n
where <state> can be 0 or 1.
Example: Query the status of digital input 1
Request:
http://myserver/cgi-bin/dido/getdi.cgi?di1
Response:
HTTP/1.0 200 OK\r\n
All manuals and user guides at all-guides.com
DESCRIPTION
0 – inactive, normal state
1 – active, triggered state
Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or
relative path according the the current path. If you omit this
parameter, it will redirect to an empty page.
64

Publicité

loading

Ce manuel est également adapté pour:

Eyseo tv7221Eyseo tv7222Eyseo tv7223