11. Functions and operation
The device may only be used by persons who have
been trained in operating the device.
Switching on the oil heating unit
room temperature:
5s
10s
5s
Switching off the oil heating unit
• Switch the device off by setting the selector switch
to the position "0".
• If you are using a thermostat, switch the device off
via the settings of the control device (e.g. by setting
the thermostat to a low temperature).
The flame is extinguished and the fan will continue
running for approx. 90 seconds in order to cool down
the burner.
m Damage to the device due to overheating!
Do not switch off the device by pulling out
the power cord. This may cause the device
to overheat. Switch the device off properly.
Only disconnect the power plug if the fan
motor has come to a complete standstill.
• Wait until the automatic after-cooling has been
completed.
• Secure the device against being accidentally
switched on again by pulling out the power cord.
B - 6
21°C
20°C
19°C
5s
0-60s
10s
5s
Operating Manual – IDE 30 / 50 / 60
0-60s
Resuming operation after a failure
During the initial commissioning of the device or after
the heating oil circuit has been completely emptied,
the inflow of heating oil to the nozzle may be insuffi-
cient. This will cause the flame control system to be
activated and the device will be blocked.
• Wait for approx. 1 minute.
• Switch on the device.
• If the device is still not starting up:
• Make sure that there is enough heating oil in
the tank.
• See the chapters "Safety equipment" and "Trouble-
shooting".
Safety equipment
The oil heating unit features an electronic flame and
maximum temperature monitoring system that uses a
photoelectric cell and a safety thermostat.
0
5s
0-60s
10s
Wait cooling-
off period!
5s
EN