Télécharger Imprimer la page

Trotec IDE 30 Manuel D'utilisation page 13

Chauffage au fioul
Masquer les pouces Voir aussi pour IDE 30:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
05. Technical data
Parameter
Article number
Electrical connection
Frequency
Nominal current max.
Air volume Air volume
Fan
Nominal heat output
Temperature increase ∆T
Oil consumption max.
Tank capacity
Chimney connection
Thermostat connection
Combustion
Sound pressure level
(at distance of 1 m)
Length
Width
Height
Weight
1) indicates the temperature increase. ΔT + ambient temperature = exhaust air temperature
2) optional
Fuels
The following fuels have been approved for use with
the oil heating unit IDE heating oil EL, diesel.
EN
Type IDE 30
Value
1.430.000.220
230 V
50 Hz
1,5 A
760 m³/h
Axial fan
30 kW
62 °C
1)
3,4 l/h
50 l
ø 120 mm
series
indirect
70 dB (A)
1100 mm
490 mm
755 mm
34,2 kg
Operating Manual – IDE 30 / 50 / 60
Type IDE 50
Value
1.430.000.230
230 V
50 Hz
3,2 A
2000 m³/h
Axial fan
32 kW
70 °C
4,8 l/h
68 l
ø 150 mm
series
indirect
75 dB (A)
1365 mm
550 mm
985 mm
56,7 kg
Type IDE 60
Value
1.430.000.230
230 V
50 Hz
3,2 A
2000 m³/h
Axial fan
32 kW
70 °C
5,2 l/h
68 l
ø 150 mm
series
indirect
75 dB (A)
1365 mm
550 mm
985 mm
56,7 kg
B - 3

Publicité

loading

Ce manuel est également adapté pour:

Ide 50Ide 60