Moteur tubulaire avec réglage automatique ou anuel des fins de course électroniques
Masquer les pouces Voir aussi pour Plug & Play 3000:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

- To prevent any danger or malfunction, the size of electrical control components
connected to the motor must be compatible with the electrical features of the motor.
- Means for disconnection must be incorporated in the fixed wiring in accordance with
the national installation standards.
- The selectors inverting the direction of rotation of the motor must be provided with
mechanical interlocking.
- Invert the brown and the black conductor to change the direction of rotation.
- NEVER connect two or more selectors to the same motor.
- For outdoor use, provide the appliance with a supply cord with designation H05RN-F
containing at least 2% of carbon.
- Cable length between motor and control-switch maximal 50 m.
In case of cable length more than 50 m an interface-relay have to be used.
ELECTRICAL CONNECTIONS
15
1- brown (UP)
2- black (DOWN)
3- blue
4- yellow-green