LIMIT SWITCHES AND OBSTACLE DETECTION
Obstacle detection in both direction is enabled only after both limit switches have been
set.
The motor also has an super-sensitivity obstacle detection in downwards, which can be
set on three levels (see page 23).
In the event an obstacle is detected, the motor will perform a safety movement in reverse.
RESTORING THE ORIGINAL CONFIGURATION
PLEASE NOTE: recovery of the default configuration will delete the limit switches
and disabling the super-sensitivity.
To restore the original motor configuration perform the procedure as described below:
- Connect both the brown and black motor wires under the same switch, e.g. UP.
- Press the UP button for at least 2 seconds.
- Disconnect and then restore the original control switch electrical connections (see
page 15).
UP
DOWN
1- Brown
2 - Black
3 - Blue
4 - Yellow-green
24