5
Initial commissioning
The control unit performs the following additional functions automatically:
Checking the battery voltage
The control unit checks the battery voltage 2x daily and signals a battery error (potential-free contact "fault") if the voltage
falls below a certain level. Optical and acoustic warning signals appear on the control unit.
SDS Self diagnosis system
The control unit has an automatic self-check, which performs a functional check of the connected components automatically.
Even if no wastewater has to be pumped away, the system's readiness is checked.
Preset test cycle:
every 28 days (freely adjustable)
5.1
Switch on and off
Connect the battery
Connect the battery connector(s) (2).
Establish mains voltage (400V control units)
Connect the mains cable to the mains power supply.
Move main switch (1) into ON position.
Initialisation starts automatically.
The device checks the electrical components.
Voltage test of the batteries.
|3.10. Language|
Menu item
Switch on
Move main switch (1) into ON position. After a successful system test, the display shows
green LED signals readiness.
If the display does not show initialisation (
the set parameters must be checked, or reset to the factory settings (
tings, the initialisation of the control unit starts automatically.
Please note that the counter for the maintenance interval is not changed by the reset to the factory settings.
5.2
Carrying out initialisation
During initialisation, the following input is expected:
|Language|
|Date / Time|
|Product type|
|System variant|
|Power rating|
|S1 / S3 operation|
|Maintenance interval|
Language
► Press OK.
► Use the cursor keys to select the language and confirm with OK.
|Date / Time|
Menu
Date / Time
► Set the respective flashing figure in date and time and confirm with OK.
|Product type|
Menu
Product type
► Select product type and confirm with OK.
Selection affects which setting options are available.
|System variant|
Menu
System variant
► Select the system variant. The system variants can be found in the respective manufacturer's documents.
Selection affects which setting options are available.
|Power rating|
Menu
010-532_13
menu appears.
|3.10. Language|
appears.
appears.
appears.
appears.
Installation and operating manual
|0 System info|
), the control unit has already been initialised. In this case,
|3.11 Reset|
). After resetting to the factory set-
and the
39 / 140