6.3
Settings
7
Troubleshooting
8025389.1K3A/2023/07/04 | SICK
Subject to change without notice
Operating reserve
100
10
1
2
1
0
2
4
6
8
(6.56)
(13.12)
(19.69)
(26.25)
Distance in m (feet)
Figure 4: Characteristic line GL6L
PL10F
1
PL20F
2
P250F
3
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Maximum distance range from reflector to sensor (operating reserve 1)
D
Recommended distance range from reflector to sensor (operating reserve 2)
blue
Recommended sensing range for the best performance
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 5-turn). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We
recommend setting the potentiometer to "Maximum". A lower operating reserve may be
necessary for depolarizing surfaces.
The sensor is adjusted and ready for operation.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 3: Troubleshooting
LED/fault pattern
Yellow LED does not light up
even though the light beam
is aligned to the reflector and
there is no object in the path of
the beam
1
0.08
2
0.08
3
0.08
0
(6.56)
A
Figure 5: Bar graph display
3
10
12
(32.81)
(39.37)
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
O P E R A T I N G I N S T R U C T I O N | GL6L
OPERATING INSTRUCTION
4.5
5.5
6.5
8
10
12
2
4
6
8
10
(13.12)
(19.69)
(26.25)
(32.81)
(39.37)
Distance in m (feet)
D
C
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
12
B
en