Trapezoid Arb (Option E36150ADVU)
Step 1– Select Arb waveform
Press Arb to access the Arb selection menu. Then select Trapezoid.
Press Back to return to Arb main menu.
Step 2 – Configure the Trapezoid Arbs
Configure the Trapezoid Arb accordingly. Refer to the below table for details.
Parameter
Available Key Settings
Arb Type
Voltage or Current
Start Setting (I0 or
minimum to maximum
V0)
Peak Setting (I1 or
minimum to maximum
V1)
Delay (t0)
0 – 3600 s
Rise time (t1)
0 – 3600 s
Peak Width (t2)
0 – 3600 s
Fall Time (t3)
0 – 3600 s
End Time (t4)
0 – 3600 s
96
Sets the output Arb type.
Default is Voltage.
Action required:
Press Arb Type to toggle between Volt and Curr.
Volt
Selects voltage as output Arb type.
Curr
Selects current as output Arb type.
Sets the setting before and after the trapezoid.
Sets the peak setting.
Sets the delay time after the trigger is received but before the trapezoid starts.
Sets the time the trapezoid ramps up.
Sets the width of the peak.
Sets the time that the trapezoid ramps down.
Sets the time the output remains at the end setting after the trapezoid completes.
Description