Operating Phases Of The Appliance; Sequence Of Ignition Phases; Eco Stop; Stand-By - Ravelli RBH 150 V Manuel D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour RBH 150 V:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
EN
Rev.2 15/07/2021
Pag.52

OPERATING PHASES OF THE APPLIANCE

Sequence of ignition phases

Modulation
During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to MODULA-
TION mode in which fuel consumption is minimum.
��
When the set room temperature is reached, the stove goes into Modula mode and the pump switches off. In the event of an
increase in the water temperature, the pump is automatically reactivated.

Eco stop

With the "COMFORT CLIMA" function activated, the stove switches off when the room / water temperature set has been reached.
With the "Summer" season set, the stove switches off when the DHW (boiler) temperature has been reached.

Stand-by

The STAND-BY mode is activated when the temperature of the water reaches 85°C, this function is aimed at protecting the circuit
especially when COMFORT CLIMATE function is not active on boiler H2O. If the boiler is not in this condition , it switches to STAND-
BY mode to guarantee protection of the hydraulic circuit. The boiler restarts automatically after it cooled down, on the condition that
heating is requested.

Sanitary

If there is an external rapid exchanger with flow switch, when the domestic water is opened the stove goes to "Sanitary" power. This
function is enabled only with scheme 0. If the stove is off, it remains off.

Description of menu functions

To access the MENU screen, press the menu access button
To scroll the menu list, use the "UP" and DOWN "buttons and then press the confirmation key to enter the submenus.
Then, to return to the "Home" screen, press the return button several times.
The stove is equipped with many functions available in each menu programming. Some of these menu are accessible for the end
user , other are protected with a password so they are accessible only for the After sales center.
MENU
USER
TECHNICIAN
PRODUCER
��
The TECHNICAL and PRODUCER menus are password protected. Changing parameters within these menus could com-
promise the operation and safety of the stove. In this case the warranty will be invalidated.
Use and maintenance manual RBH 150 V - RBH 200 V
SWITCH-ON - initial pellet loading phase;
WAIT FLAME - flame development wait phase;;
FLAME PRESENT - flame stabilization phase and reduction of combustible inside the brazier;
WORK - operation phase described in the dedicated chapter;
Menu USER
Menu TECHNICIAN
Menu PRODUCER

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rbh 200 v

Table des Matières