Environmental protection
The appliance and accessories should be recycled in an environmentally
friendly way. Do not dispose of the appliance with household waste. Support
environmental protection by taking the appliance to a local collection point or
obtain information from a specialist retailer.
Important Note regarding Product Liability!
Due to an EC ordinance in effect since 01.01.1990, the manufacturer is liable for his product
only if all parts originate from or were approved by the manufacturer and the devices
are assembled and operated correctly. The use of other accessories and spare parts can
partially or completely invalidate the liability.
Correction of Malfunctions
Problem
No coating material
emerges from the
nozzle
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
20
Cause
Nozzle clogged
Material volume setting
turned too far to the left (-)
No pressure build-up in
container
Container empty
Feed tube loose
Feed tube clogged
Coating material assembly
at air cap, nozzle or needle
Nozzle loose
Nozzle seal worn
Nozzle worn
Material volume too large
Material volume adjusting
screw turned too far to the
right (+)
Nozzle contaminated
Viscosity of coating material
too high
Too little pressure build-up
in container
Air filter heavily soiled
Coating material in
container running out
Nozzle seal worn
Air filter heavily soiled
Remedy
Clean
Turn to the right (+)
Tighten container
Refill
Insert
Clean
Clean
Union nut tighten
Change
Change
Turn material volume
adjusting screw to the
left (-)
Clean
Dilute further
Tighten container
Change
Refill
Replace
Change