3.7
smoking
A properly installed appliance should not smoke. If yours does, check the following:
Has the chimney had time to get hot?
Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
Is the smoke fl ow impeded by too long a horizontal pipe or too many bends?
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diameter of a
chimney, too short a chimney, or a chimney too close to trees or a higher roof?
Is the moisture content of the wood greater than 20%?
note:
Differences in chimney height and draft may lower overall burn times.
DO NOT OVERFIRE THE APPLIANCE! Over fi ring can occur by burning large amounts of smaller wood pieces
or vigorously burning large loads of wood for long periods of time (one or two hours).
If smoking continues to be a problem, contact your local authorized Napoleon dealer.
3.8
reloading the appliance
WARNING
!
Burning wet, unseasoned wood can cause excessive creosote accumulation, which when ignited can cause a
chimney fi re that may result in a serious house fi re.
When refuelling, open the door slowly to prevent smoke spillage. Use a pair of long heat resistant gloves when
feeding the fi re. Keep a small steel shovel nearby to use as a poker and to remove ashes. Do not store wood
within 4 feet (1.2m) of the appliance.
3.9
gas log set
WARNING
!
Only unvented gas log sets which have been found to comply with the standard for Unvented Room Heaters,
ANSI/IAS/AGA Z21.11.2, are to be operated in this appliance.
Do not operate unvented gas log sets in this appliance with the chimney removed.
Follow manufacturer's operating instructions for use of gas log sets.
When an unvented gas log set is installed, ensure the damper on the appliance is fi xed in the closed position prior
to every use.
When a vented gas log set is installed, ensure the damper is fi xed in the open position prior to every use.
operation
EN
15
W415-1697 / A / 08.27.18