Settings on the siren
•
Jamming
The siren monitors jamming independently, but does not activate itself if jamming occurs.
Jumper inserted:
Jumper removed:
•
Self-set under tampering (SAB mode)
Jumper inserted:
Jumper removed:
•
Siren unset period: The acoustic siren switches off after the defined unset period or when a unset command is
received from the control unit. The unset period changes according to the jumper position.
Jumper removed:
Jumper inserted to the left:
Jumper inserted to the right: 15 min. (default setting)
These settings do not affect the flashing LED. This switches off after 15 minutes, at the latest.
Positioning of the flashing LED bar
The flashing LED bar can be attached on the top or bottom inside the siren.
To reposition the flashing bar, first loosen the battery connections. Bend the holder clamps outwards and lift out the
flashing bar. Pay attention to cable guidance of the flashing bar in the base plate and reattach the bar into the new
position. Ensure that it is latched into place completely. Reattach the battery and close the housing. Make sure that the
lens is aligned correctly.
Jamming on – The siren informs the control unit (default setting)
Jamming off – No action
SAB on – Self-set of the siren when tamper contact is open – information sent to the
control unit. The siren switches off when the tamper contact is closed again or a response
is received from the control unit (default setting).
SAB off – No self-set when tamper contact is open, but the control unit is still informed.
Depending on the settings, the control unit then gives the order for siren set (or not).
5 sec.
3 min.
8