IMPORTANT
• A rectangular duct of 3 ¼'' x 10 '' or a round duct of a minimum of 6" (standard for this range hood) must be
used to maintain maximum airflow efficiency.
• Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to duct
provided.
VENTING METHODS
INSTALLATION DIAGRAMS
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow may be needed
This range hood is factory set for vertical venting using round or rectangular vent adapter but can be
converted to horizontal venting by swapping the round vent adapter on top with rectangular vent adapter
behind the range hood as shown below
Horizontal venting
Type 1:
3
x 10'' rectangular vent
¼''
adapter behind the range hood.
:
Option 1:
Wall cap
Type 2:
adapter on top of the range hood.
Roof cap
3
x 10'' rectangular vent
¼''
24
Option 2:
Vertical venting
Type
3:
6'' round vent adapter on the top
.