MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Open the nail guide.
3 Insert a rod into the outlet.
Tap the rod with a hammer.
Hammer
Rod
Outlet
4 Remove the jammed nail with a slotted screw
driver.
Nail
5 Cut the deformed collated wire with nippers.
Correct the deformation.
MAINTENANCE
WARNING
1
1
Disconnect
air hose
Slotted Screw Driver
6 In case of frequent jam, contact a metabo HPT
authorized service center.
2. Inspecting the push lever
1 DISCONNECT AIR HOSE.
2 Clean the push lever sliding part.
Lubricate it with metabo HPT pneumatic tool lubricant.
Lubricate
3. Inspecting the feeders
1 DISCONNECT AIR HOSE.
2 Clean the knob sliding part.
Lubricate it with metabo HPT pneumatic tool lubricant.
Nail
Guide
Knob
Push Lever
3 Open the nail guide and remove dust.
Lubricate the sliding groove of the feeder and
shafts.
Nail Guide
Main Nail Stopper
Sub Nail Stopper
English
1
Disconnect
air hose
1
Disconnect
air hose
Nose Opening
Feeder Shaft
Feeder